Aeotec Z-Wave Plus ZW100-A Multisensor 6 -------------------------------- .. image:: ../../images/motion_sensor/aeon_gen6_motion.jpg .. :align: left Product Description ~~~~~~~~~~~~~~~~~~~~~~~~~~ #. 6-in-1 Z-Wave Plus MultiSensor: motion, humidity, temperature, light lux, UV, vibration sensor #. 2 year battery life #. Super-small at 1.8 inches. Can be installed in corner, in-wall, on shelf or in downlight Working with PhD ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ #. Monitor Aeotec Multisensor 6 and other connected devices with the Zinno app available on iOS&Android #. Receive alerts from PhD if the Aeotec Multisensor 6 detects movement #. Associate Aeotec Multisensor 6 with other smart devices in Zinno App, and set them to turn on or off when sensor detects movement Add Aeotec Multisensor 6 to PhD's network ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ #. On the Zinno app, press Left Menu Bar, then select “Devices” #. Select “+” button to put the PhD in inclusion mode, keep the sensor close to PhD within 10 feet (3 meters) #. Press the Action Button on Aeotec Multisensor 6 #. If detecting a new device successfully, PhD will announce “Found Device”, and Zinno app will display the dialog box, asking user to interact with device one more time #. Repeat step #3, PhD will announce “The device is being added” #. If adding the sensor successfully, PhD will announce “Adding Aeotec Multisensor 6 success” and on Zinno app will display the dialog boxes that indicate user has added device successfully .. image:: ../../images/motion_sensor/aeon_gen6_motion_detail.png .. :align: center Specification ~~~~~~~~~~~~~~~~~~~~~~ - Model number: ZW100-A - Power source: USB DC 5V, Battery - Battery type: x2 CR123A batteries - Protocol: Z-Wave Plus - Dimension: 1.8 x 2.5 x 1.8 inches - Weight: 0.13 pounds - Color: White .. Specification .. ~~~~~~~~~~~~~~~~~~~~~~ - Model number: ZW100 - Power Supply: USB DC 5V or battery power(2×CR123A batteries, 3V, 1500mAh) - Operating Temperature: 0 C to 40 C . - Measured Temperature Range: -10 C to 50 C . Accuracy: ±0.5 C . - Humidity Range: 20%RH to 80%RH. Accuracy: ±5%RH (at 25 C ). - Lighting: 0 LUX to 1000 LUX. - Motion Sensitivity: 3 meters to 5 meters. - Water Proofing: IP20. - Wireless Range: Up to 500feet/150 metres outdoors. .. Inclusion/Exclusion to/from a network .. ~~~~~~~~~~~~~~~~~~~~~~~ #. Put controller to Inclusion/Exclusion mode #. Press program button once. Device will be included/excluded to/from zwave network. .. image:: ../../images/motion_sensor/aeon_gen6_motion_b.png .. :align: center .. Wake up information .. ~~~~~~~~~~~~~~~~~~~~~~~~~ - When battery is used, to wake up device, press and hold its Z-Wave Button for 3 seconds and then release it. Your MultiSensor’s LED should now be solid to indicate that it is active. - When completing configurating or communicating with device, to put device into sleep mode for battery saving, press and hold its Z-Wave Button for 3 seconds and then release it. - When power-supply is used, device is in waken up state always. .. Factory reset .. ~~~~~~~~~~~~~~~~~ Press and hold z-wave button for 20 seconds and then release. LED will stay in solid for 2 seconds and then turn off indicates reset successfully. .. Button pressed actions and events .. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ==================================== =============================================================================== Short 1 time pressed 1. Send non-secure node info frame 2. Add device to z-wave network 3. Remove device from z-wave network Short 2 times pressed in 1 seconds Send secure node info frame Press and hold 3 seconds Enable/disable wake up for 10 minutes Press and hold 20 seconds Reset device to factory setting ==================================== =============================================================================== .. Link in Amazon .. ~~~~~~~~~~~~~~~~~~ https://www.amazon.com/Aeotec-Multisensor-temperature-humidity-vibration/dp/B0151Z8ZQY .. Configuration description .. ~~~~~~~~~~~~~~~~~~~~~~~~~~ #. Enable wake-up device 10 minutes after re-power on (battery mode) - Parameter: 2 (0x02) - Size: 1 byte - Value: 0x00: disable others: enable - Default: 0x00 #. Auto clear motion interval - Parameter: 3 (0x03) - Size: 2 bytes - Value: 1 ~ 15300 + 1 ~ 255: unit is second + 256 ~ 15300: unit is minute with below formular a. interval = value/60 (without remainder) b. interval = value/60 + 1 (if remainder) - Default: 0x00F0 #. Motion sensity - Parameter: 4 (0x04) - Size: 1 byte - Value: + 0x00: disable + 0x01: sensity minimum level + 0x02: + 0x03: sensity medium level + 0x04 + 0x05: sensity maximum level - Default: 5 #. Motion trigger command - Parameter: 5 (0x05) - Size: 1 byte - Value: + 0x01: Basic set CC + 0x02: Sensor binary report - Default: 1 #. Configure low battery value - Parameter: 39 (0x27) - Size: 1 byte - Value: + Valid value: 10 ~ 50 + Unit percentage - Default: 20 #. Enable auto report when temperature and humidity change reach to threshold - Parameter: 40 (0x28) - Size: 1 byte - Value: + 0x00: disable this feature + 0x01: enable this feature - Default: 0 #. Temperature change threshold to send report - Parameter: 41 (0x29) - Size: 2 bytes - Value: + Unit is Farenheit for US version and Celsius for EU/AU version + High byte is threshold value. low byte is unit (0x01-celsius, 0x02=farenheit) + Threshold value contains 1 decimal point, eg: threshold = 20, it means 2.0. setting value 0x1401 means that 2.0 oC - Default: 0x14xx #. Humidity change threshold to send report - Parameter: 42 (0x2A) - Size: 1 byte - Value: + Unit is percentage + Valid value: 0x01 ~ 0x64 - Default: 0x0A #. Luminance change threshold to send report - Parameter: 43 (0x2B) - Size: 2 bytes - Value: in range - Default: 0x0064 #. Battery change - Parameter: 44 (0x2C) - Size: 1 byte - Value: + Unit is percentage + Valid value: 0x01 ~ 0x64 - Default: 0x0A #. Ultraviolet change - Parameter: 45 (0x2D) - Size: 1 byte - Value: in range - Default: 0x02 #. Low temperature threshold report - Parameter: 46 (0x2E) - Size: 1 byte - Value: + 0x00: disable + 0x01: enable - Default: 0x00 #. Report items to group 1 - Parameter: 101 (0x65) - Size: 4 bytes - Value: bit setting + bit 0: battery + bit 4: ultra-violet + bit 5: temperature + bit 6: humidity + bit 7: luminance - Default: 0x000000F1 #. Auto report interval - Parameter: 111 (0x6F) - Size: 4 bytes - Value: + Valid value: 0x05-0x28DE80 + USB power, unit is second + Battery power: value <= X*60, interval is X minutes - Default: 0x00000E10 (3600 seconds)