Fibaro Z-Wave FGFS-101 Water/Flood Sensor ------------------------------- .. image:: ../../images/water_flood/fibaro_flood_sensor.jpg .. :align: left Product Description ~~~~~~~~~~~~~~~~~~~~~~~~~~ #. Has a futuristic design, compact size, and a wide variety of additional functions #. Will alert you of a threatening flood, or a rapid temperature rise or drop #. Up to 100 foot signal range indoors. #. Mount to wall or place directly on floor. Working with PhD ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ #. Monitor your Fibaro Water/Flood Sensor and other connected devices with the Zinno app available on iOS&Android #. Receive alerts from PhD if the Fibaro Water/Flood Sensor detects detects water, or if the temperature changes #. Associate Fibaro Water/Flood Sensor with other smart devices in Zinno App, and set them to turn on or off when sensor detects water Add Everspring Water/Flood Sensor to PhD's network ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ #. On the Zinno app, press Left Menu Bar, then select “Devices” #. Select “+” button to put the PhD in inclusion mode, keep the sensor close to PhD within 3 feet (0.91 meter) #. Quickly, three times press the TMP button on the sensor #. If detecting a new device successfully, PhD will announce “Found Device”, and Zinno app will display the dialog box, asking user to interact with device one more time #. Repeat step #3, PhD will announce “The device is being added” #. If adding the sensor successfully, PhD will announce “Adding Fibaro Flood Detected Sensor success” and on Zinno app will display the dialog boxes that indicate user has added device successfully Specification ~~~~~~~~~~~~~~~~~~~~~~ - Model number: FGFS-101 - Power source: 12-24VDC, Battery - Battery type: x1 CR123A Battery - Protocol: Z-Wave - Dimension: 2.83 (Dia) x 1.1(H) inches - Weight: 0.2 pounds - Color: White .. Specification .. ~~~~~~~~~~~~~~~~~~~~~~~~ - Power Supply: 12 - 24V DC - Battery: CR123A - RF range: + 868.4 or 869.8 MHz EU; + 908.4 or 916.0 MHz US; + 921.4 or 919.8 MHz ANZ; + 869.0 MHz RU; - Operating range: up to 50m outdoors - Operating temp: 0 - 40 oC - Measure temp: -20 - 100°C .. Inclusion/Exclusion to/from a network .. ~~~~~~~~~~~~~~~~~~~~~~~ #. Put controller to Inclusion/Exclusion mode #. Press TMP button 3 times. Device will be included/excluded to/from zwave network. .. image:: ../../images/water_flood/fibaro_flood_sensor_i.png .. :align: left .. Button action and events .. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~ - 1 press: select desired MENU option (in case MENU mode is active) - 3 presses: add/remove or wake up - Press and holding: enter the MENU mode (confirmed by visual indicator) .. MENU mode & visual indicator .. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ - Flood alarm is signalled: white and blue light - In battery mode, periodically show temperature readouts via LED color - In constant powering mode, continuously show temperature readouts via LED color - Chosen MENU option is signalled with an illumination color MENU mode LED color - White: enter the MENU confirmation - GREEN: cancel alarm for associated devices - VIOLET: z-wave network's range test - YELLOW: sensor reset .. Factory reset .. ~~~~~~~~~~~~~~~~~~~~~~ Resetting the Flood Sensor: Reset procedure deletes EEPROM’s memory, including all information on the Z-Wave network and the main controller. #. Make sure the Sensor is powered #. Press and hold the TMP button #. Wait 15-20 second for visual LED indicator to glow yellow (4th position the MENU) #. Release the TMP button #. Click the TMP button, once #. After few seconds the device will be restarted, which is signalled with the red visual indicator colour and acoustic signal .. Link in Amazon .. ~~~~~~~~~~~~~~~~~~~~~~~~~ https://www.amazon.com/Fibaro-857934005140-Flood-Sensor-White/dp/B01N44GHEB .. Configuration description .. ~~~~~~~~~~~~~~~~~~~~~~~~~~ #. Alarm cancellation delay - Parameter 1 (0x01) - Size: 2 bytes - Value: + Valid value: 0x0000 - 0x0E10 + Unit is second - Default: 0 #. Acoustic and visual signals On / Off in case of flooding - Parameter 2 (0x02) - Size: 1 byte - Value: + 0x00: acoustic and visual alarms inactive + 0x01: acoustic alarm inactive, visual alarm active + 0x02: acoustic alarm active, visual alarm inactive + 0x03: acoustic and visual alarms active - Default: 0x03 #. Trigger level for associated devices - Parameter 7 (0x07) - Size: 2 bytes - Value: + 0x0001 ~ 0x0063: forced level + 0x00FF: turn device on - Default: 0x00FF #. Alarm cancellation - Parameter 9 (0x09) - Size: 1 byte - Value: + 0x00: alarm (flooding) cancellation inactive + 0x01: alarm (flooding) cancellation active - Default: 0x01 #. Temperature measurement interval - Parameter 10 (0x0A) - Size: 4 bytes - Value: + Valid value: 0x00000001 ~ 0x0000FFFF + Unit is second - Default: 0x0000012C (300 seconds) #. Temperature change level - Parameter 12 (0x0C) - Size: 2 bytes - Value: + Valid value: 0x0001 ~ 0x2710 + Unit is 0.01 oC - Default: 0x0032 (0.5 oC) #. Low temperature threshold - Parameter 50 (0x32) - Size: 2 bytes - Value: + Valid value: 0xD8F0 ~ 0x2710 + Unit is 0.01 oC - Default: 0x05DC (15 oC) #. High temperature threshold - Parameter 51 (0x33) - Size: 2 bytes - Value: + Valid value: 0xD8F0 ~ 0x2710 + Unit is 0.01 oC - Default: 0x0DAC (15 oC) #. Low temperature alarm indicator color - Parameter 61 (0x3D) - Size: 4 bytes - Value: + Valid value: 0x00000000 ~ 0x00FFFFFF + RGB value setting - Default: 0x000000FF #. High temperature alarm indicator color - Parameter 62 (0x3E) - Size: 4 bytes - Value: + Valid value: 0x00000000 ~ 0x00FFFFFF + RGB value setting - Default: 0x00FF0000 #. Managing a visual indicator under standard operation - Parameter 63 (0x3F) - Size: 1 byte - Value: + 0x00: Visual indicator does not indicate the temperature + 0x01: Visual indicator indicates the temp every measurement interval or wakeup (battery mode) + 0x02: Visual indicator indicates the temp continuously (constant mode) - Default: 0x02 #. Compensation for measured temperature - Parameter 73 (0x49) - Size: 2 bytes - Value: + Valid value: 0xD8F0 ~ 0x2710 + Unit is 0.01 oC - Default: 0x0000 #. Alarm frame activation - Parameter 74 (0x4A) - Size: 1 byte - Value: + 0x00: Tamper alarm inactive + 0x01: Button tamper alarm active + 0x02: Movement tamper alarm active + 0x03: Button and movement tamper active - Default: 0x02 #. Visual and audible alarms duration - Parameter 75 (0x4B) - Size: 4 bytes - Value: + 0x00000000: alarms active indefinitely + 0x00000001 ~ 0x0000FFFF: time in second - Default: 0x00000000 #. Re-alarm transmission when retaining flood alarm - Parameter 76 (0x4C) - Size: 4 bytes - Value: + 0x00000000: retransmission inactive + 0x00000001 ~ 0x0000FFFF: time in second - Default: 0x00000000 #. Flood sensor activation - Parameter 77 (0x4D) - Size: 1 byte - Value: + 0x00: Default flood sensor operation (flood detection, reactions) + 0x01: Built-in flood sensor TURNED OFF (does not change its state in the main controller, does not send Alarms and Basic Set frames with flood state changes. Always visible in the main controller as turned off ) - Default: 0x00 #. Associations in Z-Wave network security mode - Parameter 78 (0x4E) - Size: 1 byte - Value: bit setting + 0x00: none of the groups sent as secure + Bit 0: 2nd group ”Flood Control” sent as secure + Bit 1: 3rd group ”Flood Alarm” sent as secure + Bit 2: 4th group „Tamper” sent as secure - Default: 0x07 (enable 3 groups)